1. F.-M. Matysik, G.
Nagy,
E. Pungor: "Analytical distinction between different catechols by
means of reverse
differential
pulse voltammetry", Anal. Chim. Acta 264 (1992) 177.
2. F.-M. Matysik, H. Emons: "Convection
independent
detection with voltammetric single
microdisk electrodes",
Electroanalysis
4 (1992) 501.
3. M. Bodó, F.-M. Matysik, A.
Sarkadi,
E. Kalman, O. Elekes, L. Szporny: “New reversible
brain death model on rat:
electroanalytical results”, in E. Pungor (Ed.), Bioelectroanalysis
2, Akad. Kiadó,
Budapest,
1993, 265.
4. F.-M. Matysik, G. Werner: "Trace metal
determination
in tears by anodic stripping
voltammetry in a capillary
flow system", Analyst 118 (1993) 1523.
5. F.-M. Matysik, P. Gläser, G.
Werner:
"Analytical possibilities of microelectrode use for
stripping voltammetry",
Fresenius´ Journal of Analytical Chemistry, 349 (1994) 646.
6. F.-M. Matysik, W. Leye, H. Norr:
"In-situ-Kalibrierung
von Glaselektroden für industrielle
Messungen", Zeitschrift
der Universität Leipzig, 5/94 36.
7. F.-M. Matysik, A. Meister, G. Werner:
"Electrochemical
detection with microelectrodes in
capillary flow systems",
Anal. Chim. Acta, 305 (1995) 114.
8. R.G. Compton, F.-M. Matysik:
“Sonovoltammetric
behavior of ascorbic acid and
dehydroascorbic acid at
glassy carbon electrodes: analysis using pulsed sonovoltammetry”,
Electroanalysis, 8 (1996)
218.
9. F.-M. Matysik: “Improved end-column
amperometric
detection for capillary
electrophoresis”, J.
Chromatogr.
A, 742 (1996) 229.
10. F.-M. Matysik, U. Backofen: “Capillary
electrophoresis and capillary flow injection
analysis with
electrochemical
detection”, Fresenius´ J. Anal. Chem., 356 (1996) 169.
11. U. Backofen, F.-M. Matysik, G. Werner:
“Determination of cyanide microsamples by
means of capillary flow
injection analysis with electrochemical detection“, Fresenius´ J.
Anal. Chem., 356 (1996)
271.
12. C.M.A. Brett, A.M.O. Brett, F.-M.
Matysik,
S. Matysik, S. Kumbhat: “Nafion-coated
mercury thin film electrodes
for batch injection analysis with anodic stripping voltammetry“,
Talanta, 43 (1996) 2015.
13. A.M.O. Brett, F.-M. Matysik:
“Development
and characterization of a small volume
sonovoltammetric cell“,
Electrochim. Acta, 42 (1997) 945.
14. A.M.O. Brett, F.-M. Matysik, M.T.
Vieira:
“Thin-film gold electrodes produced by
magnetron sputtering.
Voltammetric
characteristics and application in batch injection
analysis with amperometric
detection”, Electroanalysis, 9 (1997) 209.
15. A.M.O. Brett, F.-M. Matysik:
“Voltammetric
and sonovoltammetric studies on the
oxidation of cytosine and
thymine at a glassy carbon electrode“, J. Electroanal. Chem., 42
(1997) 945.
16. F.-M. Matysik, S. Matysik, A.M.O.
Brett,
C.M.A. Brett: “Ultrasound-enhanced anodic
stripping voltammetry”,
Anal. Chem., 69 (1997) 1651.
17. A.M.O. Brett, F.-M. Matysik:
“Sonoelectrochemical
studies of guanine and guanosine“,
Bioelectrochem. Bioenerg.,
42 (1997) 111.
18. F.-M. Matysik, D.E. Khoshtariya, R.
Billing:
“Voltammetric studies of cyanometalate
complexes in highly
concentrated
aqueous solutions“, Port. Electrochim. Acta, 15 (1997)
151.
19. F.-M. Matysik: “Voltammetric
characterization
of a dual-microdisc electrode in stationary
solution“, Electrochim.
Acta, 42 (1997) 3113.
20. A.M.O. Brett, F.-M. Matysik:
“Sonoelectrochemical
determination of purine and
pyrimidine derivatives“,
Ultrasonics Sonochemistry, 4 (1997) 125.
21. A.M.O. Brett, C.M.A. Brett, F.-M.
Matysik,
S. Matysik: “Sonoelectrochemical analysis
of trace metals“,
Ultrasonics
Sonochemistry, 4 (1997) 123.
22. C.M.A. Brett, A.M. Oliveira Brett,
F.-M.
Matysik, S. Matysik: “Sonoelectrochemical
determination of trace
metals“,
in A.J. Ricco, M.A. Butler, P. Vanysek, G. Horvai, A.F.
Silva (Eds.): Chemical and
Biological Sensors and Analytical Electrochemical Methods,
The Electrochem. Soc., Inc.
(1997) 149.
23. U. Backofen, F.-M. Matysik, W.
Hoffmann,
H.-J. Ache: “Capillary batch injection
analysis using
electrochemical
detection - a reliable technique for the investigation of
nanolitre samples“, in A.J.
Ricco, M.A. Butler, P. Vanysek, G. Horvai, A.F. Silva (Eds.):
Chemical and Biological
Sensors and Analytical Electrochemical Methods, The
Electrochem. Soc., Inc.
(1997) 265.
24. S. Matysik, F.-M. Matysik, J. Mattusch,
W.-D. Einicke: “Application of
zeolite-polydimethylsiloxane
electrodes to potentiometric studies of cationic species“,
Electroanalysis, 10 (1998)
98.
25. F.-M. Matysik: “Non-aqueous capillary
electrophoresis
with electrochemical detection“,
J. Chromatogr. A, 802 (1998)
349.
26. U. Backofen, W. Hoffman, F.-M. Matysik:
“Capillary batch injection analysis: A novel
approach for studying
nanolitre
samples“, Anal. Chim. Acta, 362 (1998) 213.
27. U. Backofen, F.-M. Matysik, W.
Hoffmann:
“Elektrochemische Analytik von
Nanoliterproben:
Untersuchungen
mittels Kapillar-Batch-Injektions-Analyse”, GIT 6
(1998) 582.
28. U. Backofen, F.-M. Matysik, W.
Hoffmann,
H.-J. Ache: “Determination of ascorbic acid
in nanolitre samples by
means of capillary batch injection analysis“, Biomedical
Chromatogr., 12 (1998) 145.
29. F.-M. Matysik: “Potentialities of
electrochemical
detection in conjunction with
non-aqueous capillary
electrophoresis“,
Electrochim. Acta, 43 (1998) 3475.
30. U. Backofen, F.-M. Matysik, W.
Hoffmann:
“Capillary batch injection analysis and
capillary flow injection
analysis with electrochemical detection: A comparative study of
both methods“, Fresenius`
J. Anal. Chem., 362 (1998) 189.
31. F.-M. Matysik, L. Nyholm, K. E.
Markides:
“Comparison of µm and mm sized disk
electrodes for end-column
electrochemical detection in capillary electrophoresis”,
Fresenius’ J. Anal. Chem.,
363 (1999) 231.
32. F.-M. Matysik, F. Björefors, L.
Nyholm:
“Application of microband array electrodes for
end-column electrochemical
detection in capillary electrophoresis”, Anal. Chim. Acta, 385
(1999) 409.
33. F.-M. Matysik: “Non-aqueous capillary
electrophoresis
with electrochemical detection:
application to the
determination
of nicotine in tobacco“, J. Chromatogr. A, 853 (1999) 27.
34. F.-M. Matysik: “Studies on
water-resistant
dye compounds by means of non-aqueous
capillary electrophoresis
with electrochemical detection“, Electroanalysis, 11 (1999) 1017.
35. M. H. Gil, J. P. Sardinha, M. T.
Vieira,
M. Vivan, D. Costa, C. Rodrigues, F.-M.
Matysik, A. M. Oliveira
Brett: “Immobilization of glucose oxidase on thin-film gold
electrodes produced by
magnetron
sputtering and their application in an electrochemical
biosensor“, Biotechnological
Letters, 13 (1999) 595.
36. F.-M. Matysik: “New possibilities of
electrochemical
detection in combination with
non-aqueous capillary
electrophoresis“,
Biomedical Chromatogr., 14 (2000) 47.
37. U. Backofen, W. Hoffmann, F.-M.
Matysik:
“Determination of cannabinoids by capillary
liquid chromatography with
electrochemical detection“, Biomedical Chromatogr., 14
(2000) 49.
38. F.-M. Matysik: “Experimental
characterization
of end-column electrochemical detection in
conjunction with non-aqueous
capillary electrophoresis“, Anal. Chem., 72 (2000) 2581.
39. U. Backofen, F.-M. Matysik, W.
Hoffmann,
C.E. Lunte: “Analysis of illicit drugs by
nonaqueous capillary
electrophoresis
and electrochemical detection“, Fresenius´ J. Anal.
Chem., 367 (2000) 359.
40. F.-M. Matysik: “Elektrochemische
Detektion
für miniaturisierte Fließsysteme und
Trennverfahren“, Nachrichten
aus Chemie, Technik und Laboratorium“, 48 (2000) 632.
41. F.-M. Matysik: “End-column
electrochemical
detection for capillary electrophoresis
(Review)“, Electroanalysis,
12 (2000) 1349.
42. S. Hess, M. Dölker, D. Haferburg,
H.P. Kretscher, F.-M. Matysik, J. Ortwein, U.
Teubert, W. Zimmermann,
K. Eger: “Separation, analyses and syntheses of trimethoprim
impurities“, Die Pharmazie,
56 (2001) 306.
43. M. Bodó et al. + F.-M. Matysik:
“Screening for cerebroprotective agents using an in vivo
model of cerebral reversible
depolarization in awake rats“, Pharmacological Research, 44
(2001) 419.
44. F.-M. Matysik: “Methodenorientierte
versus
anwendungsorientierte analytische
Forschung”, Mitteilungsblatt
Fachgruppe Analytische Chemie, 2 (2001) 66.
45. S. Schermer, L. Jurica, J. Paumard, E.
Beinrohr, F.-M. Matysik, J.A.C. Broekaert:
“Optimization of
electrochemical
hydride generation in a miniaturized electrolytic flow cell
coupled to microwave-induced
plasma atomic emission spectrometry for the determination
of selenium“, Fresenius`
J. Anal. Chem., 371 (2001) 740.
46. F.-M. Matysik: “Special aspects of
detection
methodology in nonaqueous capillary
electrophoresis (Review)”,
Electrophoresis, 23 (2002) 400.
47. U. Backofen, F.-M. Matysik, C. E.
Lunte:
“Determination of cannabinoids in hair using
high pH* non-aqueous
electrolytes
and electrochemical detection: Some aspects of
sensitivity and
selectivity“,
J. Chromatogr. A, 942 (2002) 259.
48. S. Matysik, F.-M. Matysik, K.-D.
Schulze,
W.-D. Einicke: “Planare
Zeolithmembran-Elektrode
zur Bestimmung ionischer Tenside durch potentiometrische
Titration”, in H. Kaden
(Ed.) Biosystemtechnik, (2002) 197-201.
49. S. Matysik, F.-M. Matysik, W.-D.
Einicke:
“A disposable electrode based on
zeolite-polymer membranes
for potentiometric titration of ionic surfactants“, Sensors and
Actuators B, 85 (2002) 104.
50. U. Backofen, F.-M. Matysik, C. E.
Lunte:
“A simple chip-based electrophoresis system
with electrochemical
detection
and hydrodynamic injection”, Anal. Chem., 74 (2002)
4054.
51. C. E. Lunte, U. Backofen, F.-M.
Matysik:
“Chipelektrophorese: Strategien für Injektion
und Detektion”, (a) GIT,
9 (2002) 1028; (b) Bioforum 12 (2002) 841.
52. F.-M. Matysik, D. Marggraf, P.
Gläser,
J. A. C. Broekaert: “Nonaqueous capillary
electrophoresis with
indirect
electrochemical detection”, Electrophoresis, 23 (2002) 3711.
53. S. Matysik, F.-M. Matysik,
K.-D.Schulze,
W.-D. Einicke: “Impedance spectroscopic
investigations of
zeolite-polydimethylsiloxane
electrodes”, Electrochim. Acta, 48 (2002) 297.
54. F.-M. Matysik: “Miniaturization of
electroanalytical
systems”, Anal. and Bioanal. Chem., 375
(2003) 33.
55. F.-M. Matysik: "Electrochemically
assisted
injection - a new approach for hyphenation
of
electrochemistry
with capillary-based separation systems", Electrochem. Comm., 5 (2003)
1021.
56. B. Özmen, F.-M. Matysik, N.
H. Bings, J. A. C. Broekaert: "Optimization and evaluation of
different chemical and
electrochemical hydride generation systems for the determination of
arsenic
by microwave plasma torch
atomic emission spectroscopy", Spectrochim. Acta, Part B 59 (2004) 941.
57. L. Guo, F.-M. Matysik, P. Gläser:
"Speciation of organotin compounds by capillary electrophoresis:
comparison of
aqueous and mixed organic-aqueous systems", Anal. Bioanal. Chem. 380
(2004) 669.
58. S. Blasco, P. Gläser, F.-M.
Matysik:
"Development and characterization of a disposable electrochemical
detector for
capillary electrophoresis prepared by thermal lamination",
Electroanalysis 17 (2005) 1187.
59. L. Guo, F.-M. Matysik, P. Gläser,
W. Engewald: "Determination of hydrazine, monomethylhydrazine,
1,1-dimethylhydrazine, and 1,2-dimethylhydrazine by nonaqueous
capillary electrophoresis with
amperometric
detection", Electrophoresis 26 (2005) 3341.
60. A.-C. Schmidt, B. Niehus, F.-M.
Matysik, W. Engewald: "Analytik von sprengstofftypischen Verbindungen"
Laborpraxis
29 (2005) 38.
61. A. Psurek, F.-M. Matysik, G.K.E.
Scriba: "Determination of enkephalin peptides by nonaqueous
capillary
electrophoresis with electrochemical detection", Electrophoresis 27
(2006) 1199.
62. A.-C. Schmidt, B. Niehus, F.-M.
Matysik, W. Engewald: "Identification and quantification of polar
nitroaromatic
compounds in
explosive-contaminated waters by means of liquid chromatography coupled
to electrospray
ionisation
tandem mass spectrometry and additional studies by HPLC-UV",
Chromatographia 63 (2006) 1.
63. F.-M. Matysik: "Ostwalds Einfluss auf
die Entwicklung elektroanalytischer Methoden", Berichte Sächs.
Akad.
der Wiss.
63-5 (2006) 25.
64. F.-M. Matysik in U. Pyell (Ed.)
Electrokinetic Chromatography: "Amperometric Detection", J. Wiley (2006)
ISBN 0-470-87102-4,
pp 281.
65. F.-M. Matysik: "Capillary batch
injection - a new approach for sample introduction into short-length
capillary
electrophoresis with electrochemical detection", Electrochemistry
Communications 8 (2006), 1011.
66. A.-C. Schmidt, R. Herzschuh, F.-M.
Matysik, W. Engewald: "Investigation
of the ionisation and fragmentation
behaviour of different nitroaromatic compounds occurring as polar
metabolites of explosives using electrospray
ionisation
mass spectrometry", Rapid Communications in Mass Spectrometry 20 (2006)
2293.
67. S. Förster, F.-M. Matysik,
M.A. Ghanem, F. Marken: "Capillary electrophoresis with
microwave-enhanced
electrochemical detection", The Analyst 131 (2006) 1210.
68. A. Stevens, F.-M. Matysik: "Kapillar-Batch-Injektion:
Ein neues Konzept für die Kapillarelektrophorese mit
kurzen
Kapillaren - eine Alternative zur Chipelektrophorese?" in U. Guth, W.
Vonau (Eds.): "Elektrochemische
Grundlagenforschung und deren Anwendung in der Elektroanalytik", Die
Deutsche Bibliothek, 2006
ISBN
3-00-019932-2, pp 119.
69.
S. Förster, F.-M. Matysik, M. Ghanem, F. Marken:
"Kapillarelektrophorese mit Mikrowellen-assistierter
elektrochemischer Detektion" in U. Guth, W. Vonau (Eds.):
"Elektrochemische Grundlagenforschung und
deren
Anwendung in der Elektroanalytik", Die Deutsche Bibliothek, 2006
ISBN
3-00-019932-2, pp 95.
70. F.-M. Matysik, W. Engewald, U. Schumann:
"Phasenoptimierte Flüssigchromatographie von Explosivstoffen"
GIT
27, (October 2007) 9.
71. U. Schumann, F.-M. Matysik, W. Engewald: "Isokratische
Trennung von Sprengstoffen mit segmentierten Säulen"
LC-GC (2007)
34.
72. F.-M. Matysik, W. Engewald, U. Schumann:
"Phasenoptimierte LC - Beispiel Sprengstoffe", Nachrichten
aus der
Chemie 55 (2007) 1114.
73. F.-M. Matysik, U.Schumann, W.
Engewald: "Isocratic
liquid chromatography with segmented columns and
simultaneous UV and dual electrochemical detection: application to the
selectivity enhancement for the
determination of explosives", Electroanalysis 20 (2008) 98.
74. F.-M. Matysik: "Advances in
amperometric and
conductometric detection in capillary and chip-based
electrophoresis" Microchimica Acta 160 (2008) 1.
75. A.-A.Peláez-Cid, S. Blasco-Sancho, F.-M.
Matysik: "Determination of textile dyes by means of non-aqueous
capillary electrophoresis with electrochemical
detection", Talanta 74 (2008), in press.
Patents:
76. F.-M. Matysik, W. Leye, H. Norr:
"Verfahren
zum in-situ Kalibrieren von Glaselektroden
und
Vorrichtung zur Durchführung
des Verfahrens", (1993) DE 42 07 355 A1.
77. F.-M. Matysik, W. Leye:
"Verfahren zur
automatisierten pH-Messung bzw. Kalibrierung
und
Vorrichtung
zur Durchführung
des Verfahrens", (1994) DE 43 12 096 A1.
78. F.-M. Matysik:
“Amperometrisches
Detektionssystem
für die Kapillarelektrophorese“
(1996) DE
195 38 597 A1.
79. Backofen, F.-M. Matysik, W.
Hoffmann:
“Verfahren
und Vorrichtung zur Untersuchung
von
Proben im
Nanoliterbereich
mittels Kapillar-Batch-Injektions-Analyse“ (1997) DE
197 17 738 C1.
80. F.-M. Matysik:
“Elektrochemischer
Detektor
für die Kapillarelektrophorese mit wäßrigen
und
nichtwäßrigen
Puffermedien“ (1998) DE 198 57 627 A1.
81. S. Matysik, F.-M. Matysik,
W.-D.
Einicke:
“Planarer Zeolithmembransensor zur
potentiometrischen
Bestimmung von ionischen Tensiden“ (2003) DE 101 41 987 A1.